Ice Cream Mix PHE

Pioneers in the industry, we offer double stage ice cream mix phe -100 lph, double stage ice cream mix phe - 1000 lph, double stage ice cream mix phe- 200 lph, double stage ice cream mix phe- 500 lph and double stage ice cream mix phe-300 lph from India.

Double Stage Ice Cream Mix PHE -100 LPH

Request Callback

₹ 39500 / Piece Get Latest Price

Product Brochure
MaterialStainless Steel
Brand3i Tech
Medium UsedWater
Primary Exchanger MaterialSteel
Plate Heat Exchanger TypeGasketed Plate and Frame
Capacity100 LPH
Inlet Temperature80 Deg. C
Outlet Temperature8 Deg. C
Country of OriginMade in India
Plate MaterialAISI-316
Plate GasketsNitrile food grade
Gasket TypeCLIP ON
Working Pressure4 kg/cm2 (g)
Test Pressure6 kg/cm2 (g)
Ball feetAdjustable ball feet
Pressure drop product side1.0 Kg/cm2/10 MWC
Pressure drop well water side1.0 Kg/cm2/10 MWC
Pressure drop chilled side1.0 Kg/cm2/10 MWC

Minimum order quantity: 1 Piece

DOUBLE STAGE ICE CREAM MIX CHILLER
FUNCTION: The Double section Plate heat exchanger will be used for cooling the Ice Cream mix from 80 Deg. C to 45 Deg. C by mean of Well Water and then Chilling from 45 Deg. C to 8 Deg. C by mean of chilled water

FINISH: All stainless steel surfaces will be polished to 150 grit.

DESIGN PARAMETERS 

SR 

PARTICULARS 

PROCESS SIDE 

SERVICE SIDE 

 

STAGE 1ST COOLING SECTION

1

Fluid

Hot Milk

Well Water

2

Flow

100 LPH

500 LPH

3

Inlet temperature

80 Deg. C

30 Deg. C

4

Out let temperature

45 Deg. C

38 Deg. C

 

STAGE 2nd CHILLING SECTION

5

Fluid

Cool Milk

Chilled Water

6

Flow

100 LPH

300 LPH

7

Inlet temperature

45 Deg. C

1 Deg. C

8

Out let temperature

8 Deg. C

15 Deg. C

9

Process side Connection

25 mm SMS

25mm SMS


Double Stage Ice Cream Mix PHE - 1000 LPH

Request Callback

₹ 79500 / Piece Get Latest Price

Product Brochure
MaterialStainless Steel
Brand3i Tech
Medium UsedWater
Primary Exchanger MaterialSteel
Plate Heat Exchanger TypeGasketed Plate and Frame
Capacity1000 LPH
Inlet Temperature80 Deg. C
Outlet Temperature8 Deg. C
Country of OriginMade in India
Plate MaterialAISI-316
Plate GasketsNitrile food grade
Gasket TypeCLIP ON
Ball feetAdjustable ball feet
Pressure drop product side1.0 Kg/cm2/10 MWC
Pressure drop well water side1.0 Kg/cm2/10 MWC
Pressure drop chilled side1.0 Kg/cm2/10 MWC
Working Pressure4 kg/cm2 (g)
Test Pressure6 kg/cm2 (g)

Minimum order quantity: 1 Piece

DOUBLE STAGE ICE CREAM MIX CHILLER

FUNCTION:
 The Double section Plate heat exchanger will be used for cooling the Ice Cream mix from 80 Deg. C to 45 Deg. C by mean of Well Water and then Chilling from 45 Deg. C to 8 Deg. C by mean of chilled water.

FINISH: All stainless steel surfaces will be polished to 150 grit.

DESIGN PARAMETERS 

SR 

PARTICULARS 

PROCESS SIDE 

SERVICE SIDE 

 

STAGE 1ST COOLING SECTION

1

Fluid

Hot Milk

Well Water

2

Flow

1000 LPH

5000LPH

3

Inlet temperature

80 Deg. C

30 Deg. C

4

Out let temperature

45 Deg. C

38 Deg. C

 

STAGE 2nd CHILLING SECTION

5

Fluid

Cool Milk

Chilled Water

6

Flow

1000 LPH

3000 LPH

7

Inlet temperature

45 Deg. C

1 Deg. C

8

Out let temperature

8 Deg. C

15 Deg. C

9

Process side Connection

51mm SMS

51mm SMS


Double Stage Ice Cream Mix PHE- 200 LPH

Request Callback

₹ 41500 / Piece Get Latest Price

Product Brochure
MaterialStainless Steel
Brand3i Tech
Usage/ApplicationFor Dairy Industry
Medium UsedWater
Primary Exchanger MaterialSteel
Plate Heat Exchanger TypeGasketed Plate and Frame
Capacity200 LPH
Inlet Temperature80 Deg. C
Outlet Temperature8 Deg. C
Pressure4 kg/cm2 (g)
Country of OriginMade in India
Plate GasketsNitrile food grade
Gasket TypeCLIP ON
Ball feetAdjustable ball feet
Pressure drop product side1.0 Kg/cm2/10 MWC
Pressure drop well water side1.0 Kg/cm2/10 MWC
Pressure drop chilled side1.0 Kg/cm2/10 MWC
Working Pressure4 kg/cm2 (g)
Test Pressure6 kg/cm2 (g)

Minimum order quantity: 1 Piece

DOUBLE STAGE ICE CREAM MIX CHILLER

FUNCTION:
 The Double section Plate heat exchanger will be used for cooling the Ice Cream mix from 80 Deg. C to 45 Deg. C by mean of Well Water and then Chilling from 45 Deg. C to 8 Deg. C by mean of chilled water.

FINISH: All stainless steel surfaces will be polished to 150 grit

DESIGN PARAMETERS 

SR 

PARTICULARS 

PROCESS SIDE 

SERVICE SIDE

 

STAGE 1ST COOLING SECTION

1

Fluid

Hot Milk

Well Water

2

Flow

200 LPH

1000LPH

3

Inlet temperature

80 Deg. C

30 Deg. C

4

Out let temperature

45 Deg. C

38 Deg. C

 

STAGE 2nd CHILLING SECTION

5

Fluid

Cool Milk

Chilled Water

6

Flow

200 LPH

600 LPH

7

Inlet temperature

45 Deg. C

1 Deg. C

8

Out let temperature

8 Deg. C

15 Deg. C

9

Process side Connection

25 mm SMS

25mm SMS

Double Stage Ice Cream Mix PHE- 500 LPH

Request Callback

₹ 62500 / Piece Get Latest Price

Product Brochure
MaterialStainless Steel
Brand3i Tech
Usage/ApplicationFor Dairy Industry
Primary Exchanger MaterialSteel
Plate Heat Exchanger TypeGasketed Plate and Frame
Size500 LPH
Inlet Temperature80 Deg. C
Outlet Temperature8 Deg. C
Country of OriginMade in India
Plate MaterialAISI-316
Plate GasketsNitrile food grade
Gasket TypeCLIP ON
Ball feetAdjustable ball feet
Pressure drop product side1.0 Kg/cm2/10 MWC
Pressure drop well water side1.0 Kg/cm2/10 MWC
Pressure drop chilled side1.0 Kg/cm2/10 MWC
Working Pressure4 kg/cm2 (g)
Test Pressure6 kg/cm2 (g)

Minimum order quantity: 1 Piece

DOUBLE STAGE ICE CREAM MIX CHILLER

FUNCTION:
 The Double section Plate heat exchanger will be used for cooling the Ice Cream mix from 80 Deg. C to 45 Deg. C by mean of Well Water and then Chilling from 45 Deg. C to 8 Deg. C by mean of chilled water.

FINISH: All stainless steel surfaces will be polished to 150 grit

DESIGN PARAMETERS 

SR 

PARTICULARS 

PROCESS SIDE 

SERVICE SIDE

 

STAGE 1ST COOLING SECTION

1

Fluid

Hot Milk

Well Water

2

Flow

500 LPH

2500 LPH

3

Inlet temperature

80 Deg. C

30 Deg. C

4

Out let temperature

45 Deg. C

38 Deg. C

 

STAGE 2nd CHILLING SECTION

5

Fluid

Cool Milk

Chilled Water

6

Flow

500 LPH

1500 LPH

7

Inlet temperature

45 Deg. C

1 Deg. C

8

Out let temperature

8 Deg. C

15 Deg. C

9

Process side Connection

38 mm SMS

38mm SMS

Double Stage Ice Cream Mix PHE-300 LPH

Request Callback

₹ 50000 / Piece Get Latest Price

Product Brochure
MaterialStainless Steel
Brand3i Tech
Usage/ApplicationFor Dairy Industry
Medium UsedWater
Primary Exchanger MaterialSteel
Plate Heat Exchanger TypeGasketed Plate and Frame
Capacity300 LPH
Inlet Temperature80 Deg. C
Outlet Temperature8 Deg. C
Country of OriginMade in India
Plate MaterialAISI-316
Plate GasketsNitrile food grade
Gasket TypeCLIP ON
Ball feetAdjustable ball feet
Pressure drop product side1.0 Kg/cm2/10 MWC
Pressure drop well water side1.0 Kg/cm2/10 MWC
Pressure drop chilled side1.0 Kg/cm2/10 MWC
Working Pressure4 kg/cm2 (g)
Test Pressure6 kg/cm2 (g)
NO OF PLATE46 NOS

Minimum order quantity: 1 Piece

DOUBLE STAGE ICE CREAM MIX CHILLER

FUNCTION:
 The Double section Plate heat exchanger will be used for cooling the Ice Cream mix from 80 Deg. C to 45 Deg. C by mean of Well Water and then Chilling from 45 Deg. C to 8 Deg. C by mean of chilled water.

FINISH: All stainless steel surfaces will be polished to 150 grit.

DESIGN PARAMETERS 

SR 

PARTICULARS

PROCESS SIDE

SERVICE SIDE

 

STAGE 1ST COOLING SECTION

1

Fluid

Hot Milk

Well Water

2

Flow

300 LPH

1500LPH

3

Inlet temperature

80 Deg. C

30 Deg. C

4

Out let temperature

45 Deg. C

38 Deg. C



STAGE 2nd CHILLING SECTION

5

Fluid

Cool Milk

Chilled Water

6

Flow

300 LPH

900 LPH

7

Inlet temperature

45 Deg. C

1 Deg. C

8

Out let temperature

8 Deg. C

15 Deg. C

9

Process side Connection

25 mm SMS

25mm SMS

X

Contact Us

Chandra Mohan (CEO)
3I Tech Engineers
139, Greater Noida, Ecotech-3, Udyog Kendra Extn.-1
Noida - 201307, Gautam Buddha Nagar, Uttar Pradesh, India

Get Directions
Send Email
Share: