Raw Milk Chiller

Offering you a complete choice of products which include raw milk chiller-15000 lph, raw milk chiller- 20000 lph, raw milk chiller - 3000 lph and raw milk chiller-2000 lph.

Raw Milk Chiller-15000 LPH

Request Callback

₹ 188000 / Piece Get Latest Price

Product Brochure
MaterialStainless Steel
Brand3i Tech
Usage/ApplicationFor Food Processing Industry
Medium UsedWater
Primary Exchanger MaterialSteel
Plate Heat Exchanger TypeGasketed Plate and Frame
Flow Rate15000 LPH
Capacity15000 LPH
Inlet Temperature30 Deg C
Outlet Temperature4 Deg C
Country of OriginMade in India
Surface FinishChrome Finish
OperationContinuous
Gasket typeNitrile (Clip-on)
Capacity (LPH)15000 LPH
Fluid circulationMilk
Operating pressure3.5 Kg/cm 2 (g)
Design pressure5.0 Kg/cm 2 (g)
Test pressure6.0 Kg/cm 2 (g)
Heat transfer plates MOCSS AISI-316
Frame & pressure plateM.S. Cladded with AISI-304 sheet
Top & Bottom carrying barSS 304
Self-supporting frameSS 304
Tightening designMulti Bolt
Plate gasketsNitrile Food grade Quality
Thermal wellProduct/ Service Sided
MountingBall feet -Height adjustment 50mm

Minimum order quantity: 1 Piece

The Single Section plate heat exchanger will be used to chilled the Raw Milk from  30 Deg. C to 4 Deg. C by means of chilled Water.

PLATE HEAT EXCHANGER (RAW MILK CHILLER)

Operation

Continuous

Design

Single section

Gasket type

Nitrile (Clip -on)

Capacity

15000 LPH

DATA 

 

PROCESS 

SERVICE 

Fluid circulation

-

Milk

Chilled water

Flow rate

LPH

15000

45000

Inlet temperature

˚C

30

1.5

Outlet temperature

˚C

4

11

Inlet/ outlet connection

mm

63

63

Operating pressure

Kg/cm²(g)

3.5

3.0

Design pressure

Kg/cm²(g)

5.0

5.0

Test pressure

Kg/cm²(g)

6.0

6.0


Raw Milk Chiller- 20000 LPH

Request Callback

₹ 231000 / Piece Get Latest Price

Product Brochure
MaterialStainless Steel
Brand3i Tech
Usage/ApplicationFor Dairy Industry
Medium UsedWater
Primary Exchanger MaterialSteel
Plate Heat Exchanger TypeGasketed Plate and Frame
Flow Rate20000 LPH
Capacity20000 LPH
Inlet Temperature30 Deg C
Outlet Temperature4 Deg C
Country of OriginMade in India
Surface FinishChrome Finish
Material GradeSS AISI-316
OperationContinuous
Gasket typeNitrile (Clip-on)
Capacity (LPH)20000 LPH
Fluid circulationMilk
Inlet/ outlet connection63mm
Frame & pressure plateM.S. Cladded with AISI-304 sheet
Top & Bottom carrying barSS 304
Self-supporting frameSS 304
Tightening designMulti Bolt
Plate gasketsNitrile Food grade Quality
Thermal wellProduct/ Service sided
MountingBall feet -Height adjustment 50mm

Minimum order quantity: 1 Piece

The Single Section plate heat exchanger will be used chilled the Raw Milk from 30 Deg. C to 4 Deg. C by means of chilled Water.

DATA PROCESS SERVICE
Fluid circulation Milk Chilled water
Flow rate LPH 20000 60000
Inlet temperature ˚C 30 1.5
Outlet temperature ˚C 4 11
Inlet/ outlet connection mm 63 63
Operating pressure Kg/cm²(g) 3.5  3.0 
Design pressure Kg/cm²(g) 5.0  5.0 
Test pressure Kg/cm²(g) 6.0  6.0 

Raw Milk Chiller - 3000 LPH

Request Callback

₹ 82500 / Piece Get Latest Price

Product Brochure
MaterialStainless Steel
Brand3i Tech
Usage/ApplicationFor Dairy Industry
Medium UsedWater
Primary Exchanger MaterialSteel
Plate Heat Exchanger TypeGasketed Plate and Frame
Flow Rate3000 LPH
Capacity3000 LPH
Inlet Temperature30 Deg C
Outlet Temperature4 Deg C
Country of OriginMade in India
DesignSingle section
OperationContinuous
Gasket typeNitrile (Clip-On)
Fluid circulationMilk
Inlet/ outlet connection51 mm
Operating pressure3.5 Kg/cm 2 (g)
Design pressure5 Kg/cm 2 (g)
Test pressure6 Kg/cm 2 (g)
Plate MaterialSS AISI-316
Frame & pressure plateM.S. Cladded with AISI-304 sheet
Top & Bottom carrying barSS 304
Self-supporting frameSS 304
Tightening designMulti Bolt
Plate gasketsNitrile Food grade Quality
Thermal wellProduct/ Service sided
MountingBall feet -Height adjustment 50mm
No of Plate64 Nos

Minimum order quantity: 1 Piece

The Single Section plate heat exchanger will be used to chilled the Raw Milk from 30 Deg. C to 4 Deg. C by means of chilled water.

PLATE HEAT EXCHANGER (RAW MILK CHILLER)

Application

The Single Section plate heat exchanger will be used to chilled the Raw Milk from 30 Deg. C to 4 Deg. C by means of chilled Water

Operation

Continuous

Design

Single section

Gasket type

Nitrile (Clip -on)

Capacity

3000LPH

DATA 

 

PROCESS 

SERVICE

Fluid circulation

-

Milk

Chilled water

Flow rate

LPH

3000

9000

Inlet temperature

˚C

30

1.5

Outlet temperature

˚C

4

11

Inlet/ outlet connection

mm

51

51

Operating pressure

Kg/cm²(g)

3.5

3.0

Design pressure

Kg/cm²(g)

5.0

5.0

Test pressure

Kg/cm²(g)

6.0

6.0


Raw Milk Chiller-2000 LPH

Request Callback

₹ 65000 / Piece Get Latest Price

Product Brochure
MaterialStainless Steel
Brand3i Tech
Usage/ApplicationFor Dairy Industry
Medium UsedWater
Primary Exchanger MaterialSteel
Plate Heat Exchanger TypeGasketed Plate and Frame
Flow Rate2000 LPH
Capacity2000 LPH
Inlet Temperature30 Deg C
Outlet Temperature4 Deg C
Country of OriginMade in India
Surface FinishChrome Finish
Material GradeSS AISI-316
Machine CategoryRAW MILK CHILLER
OperationContinuous
Gasket typeNitrile (Clip-on)
Fluid circulationMilk
Inlet/ outlet connection51 mm
Operating pressure3.5 Kg/cm 2 (g)
Design pressure5.0 Kg/cm 2 (g)
Test pressure6.0 Kg/cm 2 (g)
Plate MaterialSS AISI-316
Frame & pressure plateM.S. Cladded with AISI-304 sheet
Top & Bottom carrying barSS 304
Self-supporting frameSS 304
Tightening designMulti Bolt
Plate gasketsNitrile Food grade Quality
Thermal wellProduct/ Service sided
MountingBall feet -Height adjustment 50mm

Minimum order quantity: 1 Piece

The Single Section plate heat exchanger will be used to chilled the Raw Milk from 30 Deg. C to 4 Deg. C by means of chilled Water.

PLATE HEAT EXCHANGER (RAW MILK CHILLER)

Application

The Single Section plate heat exchanger will be used to

chilled the Raw Milk from 30 Deg. C to 4 Deg. C by means of chilled Water

Operation

Continuous

Design

Single section

Gasket type

Nitrile (Clip -on)

Capacity

2000 LPH

DATA 

 

PROCESS 

SERVICE

Fluid circulation

-

Milk

Chilled water

Flow rate

LPH

2000

6000

Inlet temperature

˚C

30

1.5

Outlet temperature

˚C

4

11

Inlet/ outlet connection

mm

51

51

Operating pressure

Kg/cm²(g)

3.5

3.0

Design pressure

Kg/cm²(g)

5.0

5.0

Test pressure

Kg/cm²(g)

6.0

6.0

X

Contact Us

Chandra Mohan (CEO)
3I Tech Engineers
139, Greater Noida, Ecotech-3, Udyog Kendra Extn.-1
Noida - 201307, Gautam Buddha Nagar, Uttar Pradesh, India

Get Directions
Send Email
Share: